Description:

IPANOL HBC is a 100% solids, two component moisture insensitive epoxy system. IPANOL HBC is used to protect and provide an architectural finish on dry, damp or saturated surfaces.

Uses:

IPANOL HBC is used to create a smooth high gloss surface for concrete or masonry surfaces. Superior performance in protecting concrete or masonry in splash zones and in underwater applications.

Advantages:

  • Easy mixing ratio of 1 to 1 (A : B)

  • Insensitive to moisture before, during and after curing

  • Provides excellent adhesion to many common structural materials

  • Creates a hard, dense, ceramic tile like surface appearance.

 

TECHNICAL DATA

Physical Properties:

Type:

Moisture Insensitive, 100% Solids

Packaging:

4 Gallon; 10 Gallon Units ( 15.1 L; 37.9 L)

Pot Life, Neat:

35 to 50 minutes @ 75°F (24°C) (quantity dependent)

Mixing Ratio:

Part A to Part B, 1 :1 by volume

Viscosity:

Heavy Cream

Tack Free Time:

4 hrs @ 75°F (24°C)

Final cure:

7 days @ 75°F (24°C)

Elongation:

4 to 6%

Tensile Strength, ASTM D 638:   3000 psi (20.7 MPa) (14 days)

Coverage:

Coverage varies with application technique and surface characteristics. Estimated yield is as follows:

IPANOL HBC Base Coat application at a thickness of 8 to 11 mils (203 to 279 μm) will cover approximately 150 to 200 square feet per gallon (3.7 to 4.9 m2 per liter).

IPANOL HBC Top Coat applied at a thickness of 6 to 9 mils (152 to 229 μm) will cover approximately 175 to 275 square feet per gallon ( 4.3 to 6.7 m2 per liter).

Surface Preparation:

All surfaces must be clean and free of dirt, dust, oil, grease, curing compound, other coating or any contaminant that would adversely affect the bond. Surfaces must be structurally sound. All loose particles or soft unsound sections must be removed. Surfaces may be dry or damp but must be free of standing water. It is recommended that the surface be sandblasted to remove laitance on top of the concrete. Sandblasting should completely clean the concrete and expose some aggregate. A minimum of 1/16th inch ( 1.6 mm) of the concrete surface should be removed.

Mixing Instructions:

Premix components in their individual containers. Using a clean mixing container, slowly place 1 part by volume of component B into 1 part by volume of component A. Mix thoroughly for 2 to 3 minutes with a mixing paddle on slow speed (250 rpm). Mix only the amount of product that can be placed during the working life of the product. Product working time will vary according to temperature.

Do not thin IPANOL HBC with solvent. This will prevent proper curing and the physical properties of the epoxy system will not be developed.

Application:

Apply to properly prepared surfaces only. Use an airless sprayer, brush or roller with 3/8 or 7/16 inch (9.5 or 11.1 mm) nap. Apply two coats of IPANOL HBC at a thickness of 6 to 9 mils (152 to 229 μm) using brush or roller, or at 4 to 6 mils (101 to 152 μm) with a sprayer. The coating should be applied to surfaces when the ambient temperature and surface temperature will be 50°F (10°C) and rising during the next 48 hours. The second coat may be applied after the first coat is tack free.

Curing:

IPANOL HBC is self-curing.

Clean-up:

Using appropriate safety methods and protective clothing, clean equipment and tools with Xylene or Toluene. Dispose of wash solvents according to all applicable waste disposal regulations.

 

Limitations:

IPANOL HBC creates a non-breathing epoxy coating when fully cured. The coating will perform as a vapor barrier and should not be installed on surfaces in environments where moisture may form under the coating and then freeze. Such conditions would cause blistering and loss of adhesion of the coating.

The substrate should also be free of moisture that may be passing through the materials under hydrostatic pressure. Moisture under these conditions can cause incomplete bonding of the epoxy coating to the substrate.

Temperature must be at least 50°F (10ºC) and rising during the 48 hour period starting at time of installation. For best use, epoxy materials should be stored at 65°F (18.3°C) for 24 hours prior to mixing. Lower temperatures will cause thickening and increased difficulty in mixing components. Condition materials to 65°F to 85°F (18.3°C to 29.4°C) before using.

 

CAUTION – FOR INDUSTRIAL USE ONLY:

IPANOL HBC Epoxy System components contain alkaline amines. These materials are strong sensitizers and MAY CAUSE SKIN SENSITIZATION or allergic response ranging from a mild wheezing to a severe asthmatic type attack. Avoid contact with skin or eyes. IN CASE OF CONTACT immediately wash skin with soap and water. Flush eyes with water and obtain medical attention. Wear protective clothing, goggles for eyes and barrier cream on all exposed skin.

See MSDS for additional precautionary information and health hazards.

 

WARRANTY

This product is warranted and guaranteed to be of good quality.  Manufacturer, as its sole and exclusive liability hereunder, will replace material if proved defective.  THIS WARRANTY AND GUARANTEE ARE EXPRESSLY IN LIEU OF ALL OTHERS, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND MAY NOT BE EXTENDED BY REPRESENTATIVES OR ANY PERSONS, WRITTEN SALES INFORMATION, OR DRAWINGS IN ANY MANNER WHATSOEVER.

While the manufacturer recommends uses for the product based on tests believed reliable, no warranties, express or implied, or guarantee can be given as to particular methods of use or application, nor can performance be warranted, expressly or impliedly, or guaranteed under special conditions.  Distributors, salespersons or company representatives are NOT authorized to extend or vary any warranties or guarantees beyond those outlined herein nor may the manufacturer’s or seller’s limitation of liability be waived or altered in any manner whatsoever.